Error: When using Valid Frames, each Frame Range must have at least (1) Training Frame to Track. Range <manual range> does not contain any Training Frames

Brian Genna -

Error Message:

"When using Valid Frames, each Frame Range must have at least (1) Training Frame to Track.

Range <manual range> does not contain any Training Frames"

 

Cause:

When tracking in Analyzer, each separate valid section of the frame range must contain at least one training frame, even if the training frame was not used when training a model. This frame serves as an initialization frame and gives the tracker a reference point.

 

Solution:

Make sure each valid frame range (denoted by a light blue line in the timeline) that you are currently trying to track has at least one training frame.

Have more questions? Submit a request

Comments

this.location="http://support.facewaretech.com"
Powered by Zendesk